Free whole-house fan calculator. CFM = floor area × rate × (ceiling height / 8). One air change every 2 minutes is 30 ACH. Attic vents and open windows both use 1 ft² per 750 CFM. Runs in your browser; not a permit.
Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.
This page sizes a whole-house fan for a night flush. CFM = floor area × rate × (ceiling height / 8). One air change every 2 minutes is 30 ACH, which is a rate of 4 at an 8 ft ceiling. Every 3 minutes is 20 ACH. The slower range is 2 or 3 CFM/ft². Attic net free area and the open window both use 1 ft² per 750 CFM.
Not the ASHRAE 62.2 continuous ventilation rate, and not an attic-temperature fan sized from roof area over 150.
62.2 for a 2,000 ft², 3-bedroom house is about 90 CFM all day. This fan is thousands of CFM for an evening flush, plus the attic vent and the windows that have to be open.
Related calculators on this site:
Type floor area and ceiling height. Chips are 30 ACH, 20 ACH, 3 CFM/ft², and 2 CFM/ft², stored as the rate at 8 ft. You can type attic net free area you already have. The example is 2,000 ft², 8 ft, rate 4.
Floor area ft², ceiling height ft, CFM/ft² at 8 ft, existing attic NFA ft².
Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.
CFM = A × rate × (H/8);
Area, height and the rate must be positive. Existing vent area may be zero. This is not a fan curve and not a backdraft check.
Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.
Typical uses include:
1) 2,000 ft², 8 ft, 30 ACH.
2) The same house at 20 ACH.
3) The slower range, 2 or 3 CFM/ft².
None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.
The example is 2,000 ft², an 8 ft ceiling, and a rate of 4:
2,000 × 4 × (8/8) = 8,000 CFM
Volume 16,000 ft³, ACH = 30. Attic net free area and open windows are both 10.67 ft².
30 ACH is 4 CFM/ft² at an 8 ft ceiling. 20 ACH is slower. 2 and 3 CFM/ft² are the slower range.
The CFM/ft² rules assume an 8 ft ceiling. A taller ceiling is more volume, so the rate scales by H/8. That is the same as ACH × volume / 60.
Net free area, not the gross hole. Need CFM/750. A fan on a tight attic does not deliver its label.
Open windows and attic net free area use the same rule: 1 ft² per 750 CFM. A slower allowance is about 4 ft² per 1,000 CFM. Closed windows stall the fan.
No. 62.2 for 2,000 ft² and 3 bedrooms is about 90 CFM continuous. This fan’s example night flush is 8,000 CFM.
No. Outdoor air has to be cooler than the house, and combustion appliances must not be pulled backward.
2,000 ft² at 8 ft and a rate of 4 is 8,000 CFM and 30 ACH. Attic net free area and the open window are both CFM/750. A slower open-window allowance is about 4 ft² per 1,000 CFM.
Estimate only for a whole-house fan. The fan listing, attic vents and open windows prevail. Do not run it with the air conditioner.
Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.