Free baseboard length calculator. Electric feet = (BTU/h ÷ 3.412) ÷ W/ft. Hot-water feet = BTU/h ÷ BTU/h per foot. Runs in your browser; not a permit.
Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.
Ranking baseboard calculators turn a room heating load into length. Electric elements are rated in watts per foot; 250 W/ft is the preload, and 1 W is 3.412 BTU/h, so that element is about 853 BTU/h per foot. Hot-water fin-tube is rated in BTU/h per foot at a water temperature. One ranking page preloads about 580 BTU/h·ft near 180 °F average water, and lower numbers as the water gets cooler.
Not the room heat loss, and not a breaker or a wire. Length only.
The heating-load page estimates BTU/h from area. This page spends that BTU/h on feet of baseboard.
Related calculators on this site:
Type the room BTU/h. Leave the element on Electric for W/ft, or switch to Hot water and type BTU/h per foot. Example is 5,000 BTU/h at 250 W/ft.
BTU/h, electric or hot water, W/ft, BTU/h·ft.
Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.
electric ft = (BTU/h / 3.412) / (W/ft);
The load and the per-foot rating must be positive. Round up to the next foot you can buy. A 240 V element on 120 V is not this page unless you type the W/ft you will actually get.
Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.
Typical uses include:
1) 5,000 BTU/h on a 250 W/ft electric element.
2) The same load on hot water at 580 BTU/h·ft.
3) Cooler water at 450 or 330 BTU/h·ft.
None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.
The Example button uses this set:
5,000 / 3.412 = 1,465 W
1,465 / 250 = 5.86 ft, so the next foot is 6 ft.
The electric nameplate those calculators preload. 250 W is about 853 BTU/h per foot. Type the element’s number.
5,000 / 3.412 = 1,465 W. At 250 W/ft that is 5.86 ft, so a 6 ft piece.
Switch to hot water and type BTU/h per foot at your water temperature. Near 580 BTU/h·ft, 5,000 BTU/h is about 8.6 ft.
Output falls with the square of voltage. Type the W/ft you will actually get.
Not here. The heating-load page, or a room-by-room loss, supplies the BTU/h.
Not this page. It stops at length.
Composite of ranking baseboard calculators. 5,000 BTU/h at 250 W/ft is their worked electric example, about 5.86 ft. 580, 450 and 330 BTU/h·ft are catalogue-style water-temperature chips, not a reprinted rating table.
Estimate only. Read W/ft or BTU/h·ft from the element at the water temperature and voltage you will run.
Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.