Free Range hood CFM Calculator. range-hood airflow from hood length, face velocity, or a typed CFM — not from kitchen ACH. Runs in your browser; not a permit or a Manual J.
Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.
This page converts range-hood airflow from hood length, face velocity, or a typed CFM — not from kitchen ACH. It is the Range hood CFM tool in the air group on ACH Calculator.
It is not a dwelling 62.2 rate, a bath fan, or a listed makeup-air engineered system. If you need those, open a related tool instead of stretching this identity.
The identity on screen is Q = max(100 CFM, 100 or 150 CFM/ft × width, BTU/h ÷ 100). Adjacent pages keep their own inputs so you do not mix a bath-fan table with a 62.2 dwelling rate or a duct-friction takeoff.
Related calculators on this site:
Use the fields that match the job: cooktop width in inches, wall or island, optional gas burner BTU/h. Press Example to load the worked numbers. Clear empties the form. Related tools in the Next bar reuse CFM, ACH, temperatures and flows you already typed on this device.
Cooktop width (in), wall/island, optional burner BTU/h. Makeup-air flag if Q > 400 CFM.
Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.
Q = max(100, 100 or 150 CFM/ft × width, BTU/h ÷ 100)
Reject zero or negative lengths, areas, flows, pressures and absolute temperatures. ACH above about 120 is allowed for tents and cleanrooms but is flagged as unusual for occupied rooms. The 1.08, 0.68, 500 and 24 factors assume near-standard air or water; override density when you are in Denver or on glycol.
Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.
Typical uses include:
1) A 36 in residential hood at 100 CFM/ft → 300 CFM.
2) A 4 ft island hood using face area × 75 fpm.
3) Checking makeup air once hood CFM exceeds the local threshold.
If the job is life-safety, sterile, or listed equipment, stop here and use the specification.
None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.
The Example button uses this set:
30 in wall hood, 40,000 BTU/h gas
Width 250 CFM, gas 400 CFM → required 400 CFM
Work the same arithmetic on paper; the live result should match within rounding.
A hood captures at the cooking surface. Diluting the whole kitchen with ACH does not replace capture velocity.
It is a common rule of thumb for residential wall hoods, not a listed-hood rating. Recirculating hoods move grease through a filter and may be lower.
Island hoods often need more CFM because they lack a backsplash. Use face velocity × opening rather than copying a wall-hood rule.
Many US jurisdictions require makeup near 400 CFM of exhaust. Open makeup-air with this CFM as the exhaust.
Take this CFM to duct-size. 300–400 CFM is often 6–8 in round at residential velocities.
Elbows and a wall cap add static. The fan-actual tool sketches a derate; a manufacturer curve is better.
Primary identity: Q ≈ 100 CFM per linear foot of hood, or Q = V_face × A. Interpret it with the sources listed below, not as a photocopy of a copyrighted table.
Estimate only for Range hood CFM. Adopted mechanical codes, OEM curves and a licensed designer prevail.
Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.