Free Commercial exhaust CFM calculator. Room exhaust from a user-typed per-fixture or per-area rate — not a reprinted occupancy table. Runs in your browser; not a permit or a Manual J.
Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.
Ranking 62.1-style exhaust calculators split spaces into fixture counts (public toilets, showers) and area rates (janitor, locker, garage). They let you type the rate. This page does the same multiply: Q = n × CFM/unit or Q = A × CFM/ft². Chips 50 and 70 are the continuous/intermittent public-toilet pair those pages all mention; 1.0, 0.5 and 0.75 are the janitor / locker / parking figures they repeat as starting chips — you still own the rate.
It is not ASHRAE 62.1 Table 6-2 pasted into HTML. Do not treat a chip as the current standard for your occupancy.
Outdoor-air is the breathing-zone Rp+Ra form. Parking-garage already has 0.75 CFM/ft². This page is the rest of the exhaust schedule with a typed rate.
Related calculators on this site:
Pick fixture or area, type the count or ft², set the rate (chip or custom). Example is three fixtures at 50 CFM.
Mode fixture/area, fixture count, floor area, user rate with 50/70/1.0/0.5/0.75 chips.
Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.
Q = n × CFM/unit or Q = A × CFM/ft² (user-typed rates)
Reject zero or negative lengths, areas, flows, pressures and temperatures. This is a ranking-composite sketch, not a permit.
Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.
Typical uses include:
1) Public toilet, 2 WC + 1 urinal, 50 CFM continuous.
2) Janitor closet at 1.0 CFM/ft².
3) Athletic locker at 0.5 CFM/ft².
None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.
The Example button uses this set:
3 fixtures × 50 CFM = 150 CFM
Switch the mode to area and 1.0 / ft² for a janitor sketch
Public toilet exhaust is per water closet or urinal on the pages this identity follows. Lavatories are not fixtures here.
Continuous vs intermittent / heavy-use talk those pages share. Your code edition governs.
Usually a per-room rate, not per fixture. Type that rate; do not use 50 blindly.
That is a room-exhaust rate, not a Type I hood. Open commercial-hood for the hood.
Class 2/3 air is exhausted. Size makeup on makeup-air / makeup-heat.
Type the IP rate this page uses, or convert L/s·m² yourself. The multiply does not care.
Composite of ranking exhaust calculators: fixture vs area multiply, user-typed rates, common chips. Occupancy tables stay in the standard you bought.
Estimate only for commercial exhaust. The adopted 62.1/IMC edition and a licensed designer prevail.
Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.