AC Running Cost Calculator

Free air-conditioner running-cost calculator. Watts = BTU/h ÷ EER or SEER. Cost = kW × hours × duty × price. Runs in your browser; not a permit.

Updates in this browser · not a mechanical permit


Formula

Identity
W = BTU/h / rating; kWh/day = (W/1000) × hours × duty; COP = rating / 3.412
Steps

Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.

What this calculator does

Ranking running-cost calculators divide cooling capacity by the efficiency number on the label. BTU/h ÷ EER is the full-load watt. The same division with a SEER or SEER2 is how the seasonal-kWh pages work, and it is not a hot-afternoon watt. Cost is kilowatts times hours times a duty cycle times the price per kWh. COP on the efficiency pages is that rating divided by 3.412.

Not a wire size, not a breaker, and not a Manual J. The page stops at watts, kilowatt-hours and cost.

AC size on this site turns floor area into tons. This page turns a known BTU/h and a rating into electricity.

Related calculators on this site:

How to use it

Type BTU/h, the EER or SEER you want to divide by, hours per day, duty percent, price, and days. The example is 12,000 BTU/h, rating 12, 8 hours, 100% duty, $0.18/kWh, 30 days.

BTU/h, EER or SEER, hours/day, duty %, $/kWh, days.

Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.

Formula, units, and limits

W = BTU/h / rating; kWh/day = (W/1000) × hours × duty; COP = rating / 3.412

Capacity, rating and hours must be positive. Duty at 100% is the full-load sketch. A SEER pasted into this identity is a seasonal sketch, not the peak watt.

Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.

When you would use it

Typical uses include:

1) 12,000 BTU/h at rating 12, which is 1,000 W.

2) The same unit at 70% duty.

3) A 36,000 BTU/h central system with its SEER typed as the rating.

None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.

Worked example

The example is 12,000 BTU/h at a rating of 12:

12,000 / 12 = 1,000 W. COP ≈ 3.52.

1 kW × 8 h × 100% = 8 kWh/day, 240 kWh in 30 days. At $0.18 that is $1.44/day and $43.20.

FAQ

SEER in the EER box?

The identity is BTU/h divided by the number you type. EER matches a hot-afternoon watt. SEER or SEER2 is a seasonal average; the same division is the seasonal sketch, not the peak watt.

What is duty?

The fraction of the on-time the compressor actually runs. 100% is the full-load sketch of the 1,000 W example. 70% is the other common preload.

Why 12,000 and 12?

12,000 ÷ 12 = 1,000 W. At $0.18/kWh a full hour of that wattage is $0.18.

What is the COP?

The rating ÷ 3.412. A rating of 12 is a COP near 3.52. That conversion belongs to an EER, not to a SEER.

How many tons?

12,000 BTU/h is 1 ton. A 3-ton unit is 36,000 BTU/h, and the watts scale with capacity.

Wire size?

Not this page. It stops at watts, kWh and cost.

References

Watts = BTU/h ÷ the rating you type. 12,000 BTU/h at 12 is 1,000 W. Eight hours at $0.18/kWh for 30 days is $43.20. COP = rating / 3.412.

  • ASHRAE Standard 62.1 and 62.2 — outdoor-air and dwelling-ventilation forms (overview of published identities; tables remain in the licensed standard).
  • International Mechanical Code — residential bath/kitchen exhaust discussion values commonly implemented as 50/20 CFM; confirm the adopted year.
  • ASHRAE Fundamentals — moist-air relations, duct fitting concepts, fan laws, hydronic constants 500 and 1.08.
  • ISO 14644-1 — cleanroom classification names (particle limits, not a mandatory ACH).
  • Magnus / WMO saturation vapor-pressure approximations for dew point.
  • Huebscher equivalent-diameter relation for rectangular ducts.

Disclaimer

Bill estimate only. Weather, the thermostat and cycling move the real meter. Do not treat a SEER as an EER.

Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.