Free attic fan calculator. Standard attics use 0.7 CFM per ft² of attic floor. Dark or steep roofs use 0.805. Intake is 1 ft² per 300 CFM. Runs in your browser; not a permit.
Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.
This page sizes a powered attic fan. A typical attic uses 0.7 CFM per ft² of attic floor. A dark or steep roof uses 0.805, which is 15 percent more. That is about 10 air changes per hour. If you type a ridge height, the page switches to gable volume: floor × ridge height / 2, then CFM = volume × 10 / 60. Intake net free area is 1 ft² per 300 CFM.
Not the passive attic vent page. That page divides attic floor by 150 or 300. This page sizes a powered fan.
Leave ridge height blank for the 0.7 rule. Fill ridge height and the volume path takes over: gable volume is floor × height / 2, then × 10 / 60.
Related calculators on this site:
Type the attic floor area. Chips are 0.7 and 0.805. Ridge height can stay blank. The example is 1,000 ft² at 0.7.
Attic floor ft², CFM per ft², optional ridge height ft.
Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.
CFM = floor × 0.7, or × 0.805;
Floor area and the rate must be positive. Ridge height, if typed, replaces the per-square-foot rule. This does not check ceiling leaks or a ridge vent left open next to the fan.
Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.
Typical uses include:
1) 1,000 ft² standard attic, 0.7.
2) The same attic, dark or steep, 0.805.
3) 1,500 ft² with an 8 ft ridge, 10 ACH.
None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.
The example is a typical 1,000 ft² attic:
1,000 × 0.7 = 700 CFM
Intake = 700 / 300 = 2.33 ft² = 336 in².
0.7 CFM per ft² is about 10 air changes per hour in a typical attic. 1,000 ft² × 0.7 = 700 CFM.
0.805 is 0.7 plus 15 percent, for a dark or steep roof. 1,000 × 0.805 = 805 CFM.
A ridge height switches the page to volume. A gable attic is floor × ridge height / 2, then × 10 air changes per hour / 60. 1,500 ft² with an 8 ft ridge is 1,000 CFM.
1 ft² of net free intake per 300 CFM. 700 CFM needs 2.33 ft², 336 in². Without intake the fan pulls from the house.
No. The fan then pulls through the ridge instead of the soffits. Seal the ceiling, and do not leave a ridge vent open next to the fan.
No. The attic-vent page is passive net free area, floor divided by 150 or 300. This page is the powered fan CFM.
A typical attic is 0.7 CFM/ft². A dark or steep roof is 0.805. On 1,000 ft² those are 700 CFM and 805 CFM. Intake is 1 ft² of net free area per 300 CFM. With a ridge height the page uses 10 air changes per hour.
Estimate only. Seal the ceiling first. Do not run a powered fan against an open ridge vent.
Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.