Evaporative Cooler CFM Calculator

Free evaporative cooler calculator. CFM = (floor area × ceiling height) / minutes per air change. Two minutes is 30 ACH. Runs in your browser; not a permit.

Updates in this browser · not a mechanical permit


Formula

Identity
CFM = (A × H) / minutes; ACH = 60 / minutes
Steps

Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.

What this calculator does

This page sizes an evaporative cooler from the house volume. CFM = (floor area × ceiling height) / minutes per air change. Every 2 minutes is 30 air changes per hour. Every 3 minutes is 20. Above about 50 percent outdoor relative humidity the unit still moves air, but it no longer cools the room; it only adds moisture.

Not a refrigerant air conditioner, and not a whole-house fan that only moves night air.

A whole-house fan on this site is sized for a night flush. This page is the daytime evaporative unit, and it adds moisture.

Related calculators on this site:

How to use it

Type floor area, ceiling height, and minutes per air change. Chips are 2 and 3. Outdoor RH is only a warning. Example is 1,500 ft², 8 ft, 2 minutes.

Floor area ft², ceiling height ft, minutes per change, outdoor RH %.

Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.

Formula, units, and limits

CFM = (A × H) / minutes; ACH = 60 / minutes

Area, height, and minutes must be positive. Relative humidity above 50 does not change the CFM. The step line only says the cooler is the wrong machine for that weather.

Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.

When you would use it

Typical uses include:

1) 1,500 ft², 8 ft, every 2 minutes.

2) The same house every 3 minutes.

3) Outdoor RH at 60 percent, to see the warning.

None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.

Worked example

The example is a 1,500 ft² house with an 8 ft ceiling, changed every 2 minutes:

(1,500 × 8) / 2 = 6,000 CFM

ACH = 60 / 2 = 30.

FAQ

Why divide by 2?

Every 2 minutes replaces the whole house once. Volume divided by 2 minutes is the CFM, which is 30 air changes per hour.

What is the 3 minute chip?

The slower common pace is one change every 3 minutes, which is 20 ACH. A 1,500 ft² house at 8 ft is then 4,000 CFM.

Does ceiling height matter?

Yes. Airflow is floor area times ceiling height. A 10 ft ceiling is 25 percent more volume than 8 ft.

When does it stop working?

Above about 50 percent outdoor relative humidity the cooler still blows, but it stops removing heat. The step line says so. The CFM number does not change.

Do the windows stay shut?

No. The cooler has to push indoor air out, so it needs open windows or a dedicated exhaust. A closed room just gets humid.

Is 6,000 CFM a model number?

No. 6,000 CFM is airflow, not a model. A medium house is about 4,500 to 6,500 CFM. Round up to a listed unit.

References

Divide the house volume by the minutes you want one air change to take. Two minutes is 30 ACH. Three minutes is 20 ACH. A 10 ft ceiling is 25 percent more volume than 8 ft. The cooler needs open windows or a dedicated exhaust. About 4,500 to 6,500 CFM is a medium house.

  • ASHRAE Standard 62.1 and 62.2 — outdoor-air and dwelling-ventilation forms (overview of published identities; tables remain in the licensed standard).
  • International Mechanical Code — residential bath/kitchen exhaust discussion values commonly implemented as 50/20 CFM; confirm the adopted year.
  • ASHRAE Fundamentals — moist-air relations, duct fitting concepts, fan laws, hydronic constants 500 and 1.08.
  • ISO 14644-1 — cleanroom classification names (particle limits, not a mandatory ACH).
  • Magnus / WMO saturation vapor-pressure approximations for dew point.
  • Huebscher equivalent-diameter relation for rectangular ducts.

Disclaimer

Estimate only. Dry climate, open windows, and the unit listing control the result.

Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.