Guides

Each guide is a full article for one identity: what it measures, a numerical example, common mix-ups, and the calculator that does the arithmetic.

What ACH meansHow air changes relate to CFM, and which calculator to open instead.ASHRAE 62.2 dwelling ventilationWhen to open the whole-house tool instead of ACH or a bath fan.ASHRAE 62.1 outdoor airPeople + area outdoor air versus room mixing CFM.Bathroom exhaust versus ACHWhy 50 CFM and 8 ACH both appear on a bath page.Duct velocity and noiseQuiet residential fpm versus commercial mains.Equal-friction duct sizingRound stock sizes and equivalent rectangles from friction, not from a guess at 700 fpm.Fan laws in the fieldWhen a speed change is legal math, and when you need a new curve.Where 1.08 comes fromSensible BTU/h from airflow and temperature difference.400 CFM per ton350 / 400 / 450 CFM per ton chips and what they do to moisture.Psychrometric statesWhich psych tool to open for dew point, wet bulb, RH or enthalpy.The 500 constantGPM from load and ΔT, then pipe size at 2–4 fps.Makeup air after a hoodHood CFM, the 400 CFM threshold, and dedicated makeup.

What this calculator does

These guides map a job to the calculator that holds the matching identity: room ACH versus 62.2 versus a hood, equal-friction ducts, fan laws, 1.08, 400 CFM/ton, psychrometrics and the 500 constant.

They are not reprints of each tool’s full article and not a code commentary. Confirm the adopted mechanical year.

How to use it

Read the short steps, then open the linked tool and type your numbers. Guides do not calculate.

If two pages invert the same formula, the guide says which unknown belongs where.

Formula, units, and limits

No extra formula lives only in a guide. CFM = ACH × V / 60, 62.2, 62.1, Huebscher, fan laws, 1.08 and 500 are on the tools.

Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.

When you would use it

Use a guide when the nameplate unit is ambiguous (CFM versus tons versus GPM) or when bath exhaust and dwelling ventilation get confused.

None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.

Worked example

A bath that must hit 50 CFM is the bathroom-IMC guide, not the ACH guide.

A 36 in hood that then needs makeup air is the makeup-kitchen guide, not whole-house 62.2.

FAQ

Do guides replace tools?

No. They only point. Arithmetic is on the calculator.

Legal advice?

No.

Manual J walkthrough?

No. The sensible-108 guide explains the 1.08 factor only.

Languages?

Same six locales as the tools, switched in the footer.

Which first: chart or guide?

Chart for a band. Guide for which URL.

Can I skip guides?

Yes. Open All calculators if you already know the identity.

References

Disclaimer

Workflow notes. The tool page limits and the adopted code prevail.

Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size combustion air, refrigerant charge, fire dampers, medical gas, or electrical conductors.