Free pool heat-loss calculator. BTU = gallons × 8.33 × temperature rise, divided by the heat-up hours, then multiplied by climate, exposure, and cover. Runs in your browser; not a permit.
Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.
This page estimates the heat to raise a pool. Total heat = gallons × 8.33 × the rise, then divided by the hours you want that rise to take. Cold multiplies by 1.5, warm by 0.9, and a fully exposed outdoor pool by 1.3. A cover cuts about 50 to 70 percent of the heating, so the chip uses one half. A gas heater delivers about 84 percent of its input into the water, so input is the water-side rate divided by efficiency.
Not a solar-panel area, and not a heat-pump COP. The existing pool-heater page is the same water rise with no climate, wind, or cover.
Leave climate, exposure, and cover at 1 to match the plain water sum. 1.5 is cold, 0.9 is warm, 1.3 is exposed, 0.5 is a cover.
Related calculators on this site:
Type gallons, the rise, hours, and efficiency. Chips set the three factors. Example is 20,000 gal, 10°F, 24 hours, all factors 1, 84 percent.
Gallons, ΔT °F, heat-up hours, climate, exposure, cover, efficiency %.
Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.
BTU = gal × 8.33 × ΔT;
Gallons, rise, hours, and efficiency must be positive. Factors default to 1. This is the heat-up multiplied by climate, exposure, and cover. It is not a surface-evaporation model with wind speed in miles per hour.
Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.
Typical uses include:
1) 20,000 gal, 10°F, 24 h, factors at 1.
2) The same pool, cold and exposed: 1.5 and 1.3.
3) The same pool with the cover chip at 0.5.
None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.
The example is 20,000 gallons, a 10°F rise, 24 hours, and all three factors at 1:
20,000 × 8.33 × 10 = 1,666,000 BTU
1,666,000 / 24 = 69,417 BTU/h into the water. Gas input at 84 percent is 82,639 BTU/h.
About 8.33 pounds of water per gallon. The other heat-up page on this site uses 8.34. The difference is under 1 percent.
1.5 is a cold climate, 0.9 is a warm climate, and 1.3 is a fully exposed outdoor pool. Moderate weather and a sheltered pool stay at 1.
A cover cuts about 50 to 70 percent of the heating. The chip uses the 50 percent end, so the hourly rate is cut in half.
A gas heater delivers about 84 percent of its input into the water. If a heat-pump nameplate is already output, type 100.
This page uses climate and exposure multipliers. It does not ask for water surface area or a wind-speed coefficient.
The other page is gallons × 8.34 × rise / hours / efficiency, with no climate, exposure, or cover. Use this page when those three matter.
Water uses 8.33 pounds per gallon. Cold is about +50 percent, warm about −10 percent, a fully exposed outdoor pool about +30 percent. Gas delivers about 84 percent into the water. A cover is taken at the 50 percent end of a 50 to 70 percent cut.
Estimate only. A cover, the wind, and the heater listing move the real hours.
Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.