Free Wet bulb Calculator. wet-bulb from DB+RH or DB+DP, and RH from DB+WB. Runs in your browser; not a permit or a Manual J.
Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.
This page converts wet-bulb from DB+RH or DB+DP, and RH from DB+WB. It is the Wet bulb tool in the moisture group on ACH Calculator.
It is not a sling-psychrometer field procedure video or a cooling-tower approach calculator. If you need those, open a related tool instead of stretching this identity.
The identity on screen is Iterated T_wb such that h(T_db, W) ≈ h_sat(T_wb). Adjacent pages keep their own inputs so you do not mix a bath-fan table with a 62.2 dwelling rate or a duct-friction takeoff.
Related calculators on this site:
Use the fields that match the job: DB plus RH, DP, or WB. Press Example to load the worked numbers. Clear empties the form. Related tools in the Next bar reuse CFM, ACH, temperatures and flows you already typed on this device.
Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.
Iterated T_wb such that h(T_db, W) ≈ h_sat(T_wb)
Reject zero or negative lengths, areas, flows, pressures and absolute temperatures. ACH above about 120 is allowed for tents and cleanrooms but is flagged as unusual for occupied rooms. The 1.08, 0.68, 500 and 24 factors assume near-standard air or water; override density when you are in Denver or on glycol.
Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.
Typical uses include:
1) Cooling-tower 78 °F WB design.
2) Coil 55/54 DB/WB.
3) Desert 100 °F 20% RH.
If the job is life-safety, sterile, or listed equipment, stop here and use the specification.
None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.
The Example button uses this set:
100 °F
20% RH
T_wb ≈ 70 °F class sketch — computed live
Work the same arithmetic on paper; the live result should match within rounding.
This is the thermodynamic WB. A sling reads close if you actually sling.
Use the ASHRAE 1% WB for the city — a climate number, not room air.
Tower leaving water − WB. Not this page.
T_db − T_wb. Larger in dry air.
Psychrometers read frost bulb. Approximate.
h is nearly a function of WB at a given P — see enthalpy page.
Primary identity: Iterated T_wb such that h(T_db, W) ≈ h_sat(T_wb). Interpret it with the sources listed below, not as a photocopy of a copyrighted table.
Estimate only for Wet bulb. Adopted mechanical codes, OEM curves and a licensed designer prevail.
Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.