Makeup air Calculator

Free Makeup air Calculator. how much dedicated makeup airflow you still need after subtracting the exhaust you typed and an allowed uncompensated amount. Runs in your browser; not a permit or a Manual J.

Updates in this browser · not a mechanical permit


Formula

Identity
if Q_exh > 400 CFM then Q_mu ≈ Q_exh, else 0 (IRC talk; not Q_exh − 400)
Steps

Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.

What this calculator does

This page converts how much dedicated makeup airflow you still need after subtracting the exhaust you typed and an allowed uncompensated amount. It is the Makeup air tool in the air group on ACH Calculator.

It is not combustion-air for a furnace closet, a listed hood engineering report, or infiltration ACH50. If you need those, open a related tool instead of stretching this identity.

The identity on screen is: if exhaust exceeds the 400 CFM talk threshold, makeup ≈ full exhaust; otherwise 0. That is the overlap of IRC-style pages, not Q_exh − 400. Adjacent pages keep their own inputs so you do not mix a bath-fan table with a 62.2 dwelling rate or a duct-friction takeoff.

Related calculators on this site:

How to use it

Use the fields that match the job: Total exhaust CFM, allowed uncompensated CFM (chip 0 or 400 as a US common discussion value), result makeup CFM. Press Example to load the worked numbers. Clear empties the form. Related tools in the Next bar reuse CFM, ACH, temperatures and flows you already typed on this device.

Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.

Formula, units, and limits

if Q_exh > 400 CFM then Q_mu ≈ Q_exh, else 0 (IRC talk; not Q_exh − 400)

Reject zero or negative lengths, areas, flows, pressures and absolute temperatures. ACH above about 120 is allowed for tents and cleanrooms but is flagged as unusual for occupied rooms. The 1.08, 0.68, 500 and 24 factors assume near-standard air or water; override density when you are in Denver or on glycol.

Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.

When you would use it

Typical uses include:

1) 400 CFM hood, 400 allowed → 0 dedicated MU.

2) 1200 CFM hood over 400 → makeup ≈ 1200 CFM (full exhaust talk).

3) Several bath fans plus a dryer plus a hood.

If the job is life-safety, sterile, or listed equipment, stop here and use the specification.

None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.

Worked example

The Example button uses this set:

Q_exh = 1200 CFM

Q_allow = 400 CFM

Q_mu ≈ 1200 CFM (full exhaust, not 800)

Work the same arithmetic on paper; the live result should match within rounding.

FAQ

Why 400 CFM?

Many US mechanical codes discuss makeup when residential exhaust exceeds about 400 CFM. It is a talking chip, not every jurisdiction.

Can infiltration be the makeup?

Some leakage always occurs. Dedicated MU is for when you do not want to depressurize the house or steal from a furnace.

Tempered or raw?

Cold climates usually temper MU. This page only sizes airflow.

Kitchen plus baths?

Sum the exhaust that can run together, then subtract the allowed remainder.

Interlocked fan?

Interlock MU with the hood so you do not heat/cool MU 24/7. Controls are not calculated here.

Duct the MU to the hood?

Some listed systems do. This identity is a CFM balance, not a capture-hood design.

References

Primary identity: if Q_exh > 400 CFM then Q_mu ≈ Q_exh, else 0. Interpret it with the sources listed below, not as a photocopy of a copyrighted table.

  • ASHRAE Standard 62.1 and 62.2 — outdoor-air and dwelling-ventilation forms (overview of published identities; tables remain in the licensed standard).
  • International Mechanical Code — residential bath/kitchen exhaust discussion values commonly implemented as 50/20 CFM; confirm the adopted year.
  • ASHRAE Fundamentals — moist-air relations, duct fitting concepts, fan laws, hydronic constants 500 and 1.08.
  • ISO 14644-1 — cleanroom classification names (particle limits, not a mandatory ACH).
  • Magnus / WMO saturation vapor-pressure approximations for dew point.
  • Huebscher equivalent-diameter relation for rectangular ducts.

Disclaimer

Estimate only for Makeup air. Adopted mechanical codes, OEM curves and a licensed designer prevail.

Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.