Free Grow tent CFM Calculator. grow-tent exhaust from tent volume, a target air-change rate, and an optional carbon-filter derate. Runs in your browser; not a permit or a Manual J.
Estimate only. Use the adopted mechanical code, nameplate curves and a licensed designer. Not Manual J, not a listed hood, not electrical sizing.
This page converts grow-tent exhaust from tent volume, a target air-change rate, and an optional carbon-filter derate. It is the Grow tent CFM tool in the air group on ACH Calculator.
It is not a PPFD lighting calc, a VPD horticulture model, or a listed hazardous exhaust. If you need those, open a related tool instead of stretching this identity.
The identity on screen is Q = V × exchanges/min × (1 + filter%) × lights. Ranking tent pages overlap on one exchange per minute plus about 25% for a carbon filter, not a user ACH of 60. Adjacent pages keep their own inputs so you do not mix a bath-fan table with a 62.2 dwelling rate or a duct-friction takeoff.
Related calculators on this site:
Use the fields that match the job: Tent L×W×H, exchanges per minute (default 1), filter extra % (default 25), lights factor. Press Example to load the worked numbers. Clear empties the form. Related tools in the Next bar reuse CFM, ACH, temperatures and flows you already typed on this device.
Values update in this browser as you type. Use Example for the same numbers as the worked section. Copy puts the result on the clipboard. Next links reuse the last CFM, ACH and temperatures you typed on this device.
Q = V × exchanges/min × (1 + filter%) × lights
Reject zero or negative lengths, areas, flows, pressures and absolute temperatures. ACH above about 120 is allowed for tents and cleanrooms but is flagged as unusual for occupied rooms. The 1.08, 0.68, 500 and 24 factors assume near-standard air or water; override density when you are in Denver or on glycol.
Inch-pound identities (CFM, ft, in. w.g., BTU/h, GPM) are the US HVAC default. SI chips use m³/h or L/s, metres, Pa, kW and L/s. 1 CFM ≈ 1.699 m³/h ≈ 0.472 L/s. 1 in. w.g. ≈ 249 Pa. Air density 0.075 lb/ft³ and the 1.08 / 0.68 / 500 / 24 factors assume near-standard air or water unless you override them.
Typical uses include:
1) 4×4×6.5 ft tent at 1 exchange/min.
2) Carbon filter 30% derate.
3) Intake vs exhaust sizing the same CFM.
If the job is life-safety, sterile, or listed equipment, stop here and use the specification.
None of these sketches replace a licensed mechanical engineer, a Manual J/D/S, a listed-hood submittal, or the mechanical code adopted on the job. Cleanrooms, health-care, and fire/smoke exhaust need those specifications.
The Example button uses this set:
4×4×6.5 = 104 ft³
1 exchange/min → 104 CFM
+25% filter × 1 light → 130 CFM fan
Work the same arithmetic on paper; the live result should match within rounding.
Hobby tents often size near one air change per minute so odor and heat leave. It is not a plant-science law.
Carbon filters and ducting cut airflow. 20–40% is a common user band; type the filter’s own curve if you have it.
This page is air changes. Heat is a sensible-load problem — open sensible-heat with the same CFM.
Exhaust slightly more than intake if you want odor containment. Type the exhaust CFM here.
Sum volumes or run two calculations. Duct tees add fitting loss.
If you seal and inject CO2 you may not want 60 ACH. Use a custom low ACH.
Primary identity: Q = V × exchanges/min × (1 + filter%) × lights. Interpret it with the sources listed below, not as a photocopy of a copyrighted table.
Estimate only for Grow tent CFM. Adopted mechanical codes, OEM curves and a licensed designer prevail.
Results are estimates computed on your device. Nameplate curves, TAB measurements, and the authority having jurisdiction control the installation. This site does not size refrigerant charge, fire dampers, medical gas, or electrical conductors.