US residential mechanical talk (IRC M1503-style discussion) starts paying attention when a range hood or other exhaust can exceed about 400 CFM. Several ranking makeup calculators that follow that talk set dedicated makeup ≈ the exhaust airflow once you are over the threshold, and 0 below it. Subtracting 400 from 1,200 and calling 800 CFM “makeup” is a DIY shortcut; it still leaves the house 1,200 CFM negative if the hood is the only large exhaust running. This site’s makeup tool follows the threshold rule: 1,200 CFM hood, 400 allow → 1,200 CFM makeup flagged.
Hood CFM itself is not ACH. Wall cooktops often 100 CFM per foot of width, islands 150 CFM per foot, and a gas check of burner BTU/h ÷ 100, with a 100 CFM floor — that is kitchen hood. Makeup air should be tempered in cold climates and interlocked so it does not heat the neighborhood 24/7.
Worked numbers
30 in wall cooktop, 40,000 BTU/h burners: width rule 100 × 2.5 = 250 CFM, gas rule 400 CFM, floor 100 → 400 CFM, at the talk threshold. 48 in island, 60,000 BTU/h: 150 × 4 = 600, gas 600 → 600 CFM, makeup ≈ 600 CFM.
Open makeup air after the hood page. Bath fans plus a dryer belong in the exhaust total if they can run with the hood.
FAQ
Is 400 CFM every jurisdiction?
No. It is a common US discussion threshold. Read the adopted IRC/IMC year.
Can windows be makeup?
Some listings allow it; combustion appliances and comfort often disagree. Dedicated MU is the conservative sketch.
Duct MU into the hood?
Only if the hood is listed that way. Otherwise dump tempered air nearby so capture still works.
ERVs as makeup?
An ERV is 62.2 dwelling air. A 1,200 CFM hood needs a much larger path.
Fireplaces?
Depressurization spills combustion products. That is why MU exists. This page does not size chimneys.
Limits
Not a listed hood engineering report and not combustion-air for a furnace closet.
Estimates only. Adopted mechanical code, nameplate curves, TAB readings and a licensed designer prevail. This is not Manual J, not a listed-hood submittal, and not a permit drawing.