| Mode | CFM often discussed |
|---|---|
| Intermittent dwelling bath | 50 |
| Continuous dwelling bath | 20 |
| Toilet-only (some tables) | 25–50 |
The live bathroom fan tool does not stop at 50. It takes L × W × H, toilets, showers, tubs and jetted tubs, then governing = max(code floor, HVI-style area/fixtures, 8 ACH) and the next common fan. A 10 × 8 × 8 room with one shower often buys 110 CFM, not 50.
FAQ
Commercial restroom?
Different IMC table (CFM per fixture). Not this dwelling chart.
Kitchen on this table?
No. Open kitchen hood.
Sones?
Noise ratings are OEM. Lower sone often means a different housing, not a different CFM identity.
Makeup?
One 50 CFM bath rarely. Many baths plus a hood: makeup-air.
IRC versus IMC?
Dwelling baths often live in IRC. Adopted year wins.
Limits
Not HVI publication 911 reprinted as a copyrighted table.
Estimates only. Adopted mechanical code, nameplate curves, TAB readings and a licensed designer prevail. This is not Manual J, not a listed-hood submittal, and not a permit drawing.